Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Orofac Orthop ; 84(Suppl 2): 123-132, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35190866

RESUMEN

OBJECTIVES: The aim of this study was to assess the influence of surface treatment on the shear bond strength of two different adhesive-coated orthodontic ceramic brackets to computer-aided design/computer-aided manufacturing (CAD/CAM) nanohybrid composite. METHODS: A total of 120 specimens (10 mmâ€¯× 10 mmâ€¯× 3 mm) were prepared from each type of CAD/CAM block (Grandio [GR], VOCO Cuxhaven, Germany; Lava Ultimate [LU], 3M ESPE, St. Paul, MN, USA). For each type of CAD/CAM block, the plates were divided into four groups based on the applied surface treatment: hydrofluoric acid (HF), grinding bur (GB), silica coating with CoJet system (CS), and titanium tetrafluoride (TiF4) 2 wt/v%. Maxillary central incisors of adhesive-coated ceramic orthodontic brackets (APC Flash-free Clarity Advanced Ceramic, 3M Unitek, Monrovia, CA, USA) were bonded using Transbond XT Primer (3M Unitek, Monrovia, CA, USA). Shear bond strength was conducted, and the modes of failure were assessed utilizing the adhesive remnant index. Surface roughness and topography of treated CAD/CAM were evaluated. Data were statistically analyzed using two-way analysis of variance (ANOVA) and Tukey's test. The Weibull analysis was conducted on shear bond strength data. RESULTS: Surface treatment with 2% TiF4 wt/v revealed significantly higher bond strength (GR, 14.51 ± 2.57 MPa; LU, 11.19 ± 2.17 MPa) than other groups for both types of CAD/CAM restorative materials (p < 0.05). Adhesive failures were the predominant mode of failure. Surface treatment with CS revealed higher surface roughness than other groups (p < 0.05). CONCLUSIONS: Surface treatment with 2% TiF4 wt/v enhanced the adhesion between orthodontic ceramic brackets to GR and LU CAD/CAM composite restorative materials. GR CAD/CAM nanohybrid composite had higher bond strength than LU to ceramic orthodontic brackets.


Asunto(s)
Recubrimiento Dental Adhesivo , Soportes Ortodóncicos , Cerámica/química , Materiales Dentales/química , Cementos de Resina/química , Diseño Asistido por Computadora , Alemania , Propiedades de Superficie , Resistencia al Corte , Ensayo de Materiales
2.
Quintessence Int ; 54(2): 92-99, 2023 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-36421046

RESUMEN

OBJECTIVE: The aim of this prospective, double-blind, randomized controlled trial was to compare the effect of oral premedication of meloxicam, ketorolac, dexamethasone, ibuprofen, or placebo on the success of inferior alveolar nerve blocks (IANB) of mandibular posterior teeth in patients experiencing symptomatic irreversible pulpitis. METHOD AND MATERIALS: Two hundred and fifty emergency patients in moderate to severe pain diagnosed with symptomatic irreversible pulpitis of a mandibular first or second molar randomly received, in a double-blind manner, identical capsules containing either meloxicam 7.5 mg, ketorolac 10 mg, dexamethasone 0.5 mg, ibuprofen 600 mg, or placebo 60 minutes before the administration of an IANB. Profound lip numbness was assessed after 15 minutes. Access cavities were then prepared and success of IANB was defined as no or mild pain (Heft-Parker visual analog scale recordings) during access preparation and root canal instrumentation. The data were analyzed using chi-square and Kruskal-Wallis tests. RESULTS: The overall success rates for the meloxicam 7.5 mg, ketorolac 10 mg, dexamethasone 0.5 mg, and ibuprofen 600 mg groups were 52%, 64%, 54%, and 58%, respectively, with no significant differences in success rates among the premedications groups (P > .05). However, the tested premedications revealed significant differences compared with the placebo group (32% success rate) (P < .05). CONCLUSION: Premedication with meloxicam, ketorolac, dexamethasone, and ibuprofen increased the efficacy of IANB in mandibular molars with symptomatic irreversible pulpitis. (Quintessence Int 2023;54:92-99; doi: 10.3290/j.qi.b3605097).


Asunto(s)
Anestesia Dental , Bloqueo Nervioso , Pulpitis , Humanos , Ibuprofeno/uso terapéutico , Ibuprofeno/farmacología , Ketorolaco/farmacología , Meloxicam/farmacología , Pulpitis/tratamiento farmacológico , Pulpitis/cirugía , Estudios Prospectivos , Nervio Mandibular , Premedicación , Dexametasona/farmacología , Dolor , Método Doble Ciego , Anestésicos Locales , Anestesia Dental/métodos , Lidocaína/farmacología
3.
Aust Endod J ; 49(1): 165-173, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35759555

RESUMEN

The purpose of this double-blind clinical trial was to compare the effect of preoperative tramadol 50 mg, tramadol 100 mg, ibuprofen 600 mg, ibuprofen 600 mg/acetaminophen 1000 mg or placebo 60 min before the administration of inferior alveolar nerve blocks (IANB) of mandibular teeth in patients experiencing symptomatic irreversible pulpitis (SIP). Two hundred and fifty emergency patients diagnosed with SIP were randomly divided into five groups and received medications. Endodontic access was begun 15 min after completion of the IANB, and all patients had profound lip numbness. The Heft-Parker visual analogue scale was used to evaluate pain. Premedication with tramadol 100 mg significantly increased the success rate to 62% than the other groups (p < 0.05). The success rates of ibuprofen, ibuprofen/acetaminophen and tramadol 50 mg groups were not significantly different (p > 0.05). Premedication with tramadol 100 mg enhanced the anaesthetic success of IANB in mandibular molars with SIP.


Asunto(s)
Anestesia Dental , Bloqueo Nervioso , Pulpitis , Tramadol , Humanos , Ibuprofeno/uso terapéutico , Acetaminofén/uso terapéutico , Tramadol/farmacología , Pulpitis/cirugía , Nervio Mandibular , Anestésicos Locales , Método Doble Ciego , Lidocaína/farmacología
4.
BMC Oral Health ; 22(1): 96, 2022 03 27.
Artículo en Inglés | MEDLINE | ID: mdl-35346162

RESUMEN

BACKGROUND: The purpose of this study was to evaluate the optical properties of nanohybrid Grandio (GR) and nanoceramic Lava Ultimate (LU) CAD/CAM restorative materials subjected to different beverage solutions and subsequently bleached. METHODS: Five groups of each restorative material (n = 20/group, shade A2-high translucent) were immersed in distilled water, coffee, tea, cola, and ginger for one week. Changes in whiteness index, translucency parameter, and color changes of the specimens were evaluated. The data of color measurements after staining, bleaching, and the residual differences were statistically analyzed using Kruskal-Wallis and Mann-Whitney U tests at the significance level of P < 0.05. RESULTS: LU and GR revealed the highest differences in whiteness index after coffee staining (P < 0.001). GR revealed lower translucency parameter differences after staining with coffee than LU (P = 0.007). There were no significant differences in translucency changes between LU and GR after staining with tea, cola, or ginger (P > 0.05). LU revealed significantly greater color changes than GR after staining (P < 0.001). CONCLUSIONS: LU nanoceramic CAD/CAM restorative material revealed higher color changes than GR nanohybrid material. Staining beverage solutions had a distinct influence on the optical properties of the tested CAD/CAM restorative materials.


Asunto(s)
Bebidas , Color , Humanos , Ensayo de Materiales , Coloración y Etiquetado , Propiedades de Superficie
5.
BMC Oral Health ; 21(1): 131, 2021 03 19.
Artículo en Inglés | MEDLINE | ID: mdl-33740953

RESUMEN

BACKGROUND: To evaluate the effect of surface treatments on the push-out bond strength of Biodentine (BD) and white mineral trioxide aggregate (WMTA) to fiber posts. METHODS: Two brands of fiber posts were used: Reblida post; RP and RelyX post; RX. Each type of post (n = 80/group) was divided into four groups (n = 20/group) and exposed to surface treatment as follows: Control (no treatment), sandblasting (SB), hydrofluoric acid (HF), and TiF4 4 wt/v%. Each group was further subdivided into two subgroups (n = 10/subgroup) based on the type of CSCs used as follows: Subgroup A: BD and Subgroup B: WMTA. Push-out bond strength of BD and WMTA to glass fiber posts was assessed. Data were statistically analyzed using three-way ANOVA and Tukey's test. A Weibull analysis was performed on the push-out bond strength data. RESULTS: BD showed higher bond strength than WMTA (P < 0.001). The push-out bond strength for posts treated with TiF4 4 wt/v% showed greater bond strength than the other surface treatments (P < 0.05). The BD/RP-TiF4 4 wt/v% showed the greater characteristic bond strength (σ0) (15.93) compared with the other groups. Surface treatments modified the surface topography of glass fiber posts. CONCLUSIONS: The BD/RP-TiF4 4 wt/v% showed greater bond strength compared with the other groups. The TiF4 4 wt/v% surface treatment enhanced the bond strength of BD and WMTA to glass fiber posts than the other treatments. Surface treatment of fiber post with TiF4 4 wt/v% could be used to improve the bond strength with calcium silicate-based cements.


Asunto(s)
Recubrimiento Dental Adhesivo , Técnica de Perno Muñón , Compuestos de Calcio , Análisis del Estrés Dental , Humanos , Ensayo de Materiales , Cementos de Resina , Silicatos
6.
Clin Oral Investig ; 25(3): 1319-1326, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32617780

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate the effect of simulated gastric acid solution on surface topography and bending properties of esthetic coated nickel-titanium (NiTi) archwires. MATERIALS AND METHODS: Three brands of as-received white-coated superelastic NiTi upper archwires were used in this study: Dany, Perfect, and Nitanium. Uncoated metallic areas for each white-coated NiTi archwire were used for comparison with the coated areas. The specimens for each archwire were divided into two groups according to coating as follows: Group A, uncoated, and group B, coated. Then, each group was further subdivided into two subgroups according to the immersion medium as follows: Subgroup 1, immersed in artificial saliva, and subgroup 2, immersed in simulated gastric acid. Surface roughness, surface morphology, and three-point bending test were performed. The data were analyzed statistically using ANOVA and Tukey test. RESULTS: The archwires immersed in simulated gastric acid solution showed significantly higher surface roughness and lower forces on loading and unloading than the archwires immersed in artificial saliva (P < 0.001). Perfect archwire showed significantly the highest surface roughness compared with Dany and Nitanium archwires (P < 0.001). The uncoated archwires showed higher loading and unloading forces compared with coated archwires for all groups (P < 0.001). Nitanium archwire showed the lowest loading and unloading forces at different deflections (P < 0.001). CONCLUSIONS: The simulated gastric acid solution decreased considerably the amount of force applied at a given deflection. The loading-deflection and surface roughness properties of coated archwires were affected by the type of coating material. CLINICAL RELEVANCE: The impact of gastric acids on surface and mechanical properties of orthodontic archwires depend on type of coating materials.


Asunto(s)
Níquel , Titanio , Aleaciones Dentales , Estética Dental , Ácido Gástrico , Ensayo de Materiales , Alambres para Ortodoncia , Propiedades de Superficie
7.
J Adhes Dent ; 22(2): 195-204, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32322840

RESUMEN

PURPOSE: To evaluate the effect of surface treatments and aging on the bond strength of composite cement to a novel CAD/CAM nanohybrid composite. MATERIALS AND METHODS: Microtensile bond strength (µTBS) of a dual-curing composite cement (Bifix QM; BQ) to three CAD/CAM restorative materials (Grandio [GR], Vita Enamic [VE], and Lava Ultimate [LU]) was evaluated after different surface treatments. The surfaces of specimens received the following treatments: control (no treatment), sandblasting (SB), SB + silane (Ceramic Bond; CB), hydrofluoric acid (HF), HF + CB, TiF4 2 wt/v%, TiF4 2 wt/v% + CB, TiF4 4 wt/v%, and TiF4 4 wt/v% + CB. Half of the specimens in each group were aged. Surface topography and surface roughness were evaluated. Statistical analysis was conducted using ANOVA and Tukey's test. The Weibull analysis was conducted on µTBS data of aged groups. RESULTS: The µTBS was significantly affected by the type of CAD/CAM material, type of treatment, and aging (p < 0.001). Silane application significantly improved the µTBS (p < 0.05). The µTBS decreased significantly with aging (5000 thermocycles) (p < 0.05). BQ cement resulted in the highest µTBS to GR treated with TiF4 2% wt/v + CB compared to the other groups (p < 0.05). Aged GR/BQ treated with TiF4 2% wt/v + CB had the highest predicted µTBS (19 MPa). CONCLUSION: TiF4 2% wt/v followed by silane application enhanced the adhesion of GR/BQ and LU/BQ systems. On the other hand, HF surface treatment followed by silane application improved the adhesion of the VE/BQ system.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos de Resina , Cementos Dentales , Ensayo de Materiales , Propiedades de Superficie
8.
Aust Endod J ; 46(2): 226-233, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32022376

RESUMEN

This study evaluated the dynamic cyclic and torsional fatigue resistance of recently introduced TruNatomy instruments (TRN) and compare with HyFlex CM (HFC), Vortex Blue (VB) and FlexMaster (FM) instruments. Size 20, 0.04 taper of TRN, HFC, VB and FM instruments was tested for dynamic cyclic and torsional fatigue resistance. Dynamic cyclic fatigue resistance was evaluated using an artificial canal with a radius of 5 mm and a 90° angle of curvature. The number of cycles to failure (NCF) was calculated. The dynamic torsional fatigue resistance was evaluated by holding a 5 mm of the tip of each instrument in a metal block with composite resin. Torsional fatigue resistance was recorded by counting the number of load applications before fracture for each instrument. The HFC instruments had greater fatigue resistance than VB, TRN and FM. FM had a higher resistance to torsional stress than TRN, HFC and VB instruments.


Asunto(s)
Níquel , Titanio , Aleaciones Dentales , Instrumentos Dentales , Diseño de Equipo , Falla de Equipo , Ensayo de Materiales , Preparación del Conducto Radicular , Estrés Mecánico
9.
BMC Oral Health ; 20(1): 38, 2020 02 04.
Artículo en Inglés | MEDLINE | ID: mdl-32019522

RESUMEN

BACKGROUND: The purpose of this study was to compare the cyclic fatigue resistance of newly developed TruNatomy instruments (TRN) in single and double (S-shaped) curvature canals with HyFlex CM (HCM), Vortex Blue (VB) and RaCe (RC) instruments. METHODS: Size 20/.04 taper and size 25/0.04 of HCM, VB and RC were used. For TRN instruments, size 20/.04 taper (small) and size 26/.04 taper (prime) were used. The instruments were tested in artificial canals with double curvature (coronal curve; 60° curvature, 5 mm radius and apical curve; 70° curvature and 2 mm radius) and single curvature (60° curvature, 5 mm radius). The number of cycles to failure (NCF) was recorded. Data were statistically analyzed by Kruskal-Wallis and Dunn's multiple comparison tests. Weibull analysis was performed on NCF data. Statistical significant was set at p < 0.05. RESULTS: TRN and HCM revealed higher NCF compared with the other instruments for both tested sizes in single and double curvature canals (p < 0.05). TRN and HCM showed no statistically significant difference in the NCF (p > 0.05). The probability of survival was higher for HCM and TRN instruments than VB and RC instruments. CONCLUSIONS: HCM and TRN instruments were more resistant to cyclic fatigue than VB and RC instruments in single and double curvature canals. HCM and TRN instruments were anticipated to survive with higher number of cycles than the other tested instruments. RC instrument had the lowest fatigue resistance than the other instruments.


Asunto(s)
Aleaciones Dentales , Instrumentos Dentales , Cavidad Pulpar/anatomía & histología , Níquel , Preparación del Conducto Radicular/instrumentación , Preparación del Conducto Radicular/métodos , Titanio , Análisis del Estrés Dental , Diseño de Equipo , Falla de Equipo , Humanos , Ensayo de Materiales
10.
Clin Oral Investig ; 24(3): 1333-1338, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31309344

RESUMEN

OBJECTIVE: The aim of this study was to evaluate the fracture resistance of simulated immature roots using Biodentine (BD) and fiber post (FP) compared with different root canal-filling materials under aging conditions. MATERIALS AND METHODS: One hundred and forty maxillary central anterior teeth were randomly divided into seven groups (n = 20/group). Negative control received no treatment. In the other groups, the root canals were prepared to simulate immature teeth. The root canals were filled with a 4-mm apical plug of BD and restored intraradicular with BD, BD + FP, composite resin (CR), CR + FP, and gutta-percha (GP). Positive controls were instrumented but without restoration. Teeth were subjected to thermocycling and received cyclic loading before fracture resistance test. Fracture resistance was conducted using a universal testing machine with a crosshead speed of 0.5 mm/min until fracture. Load to fracture was recorded in newtons (N). Data were statistically analyzed using one-way analysis of variance and Tukey's test at P < 0.05. RESULTS: Root canals restored intraradicular with BD + FP and CR + FP showed the highest fracture resistance compared with the other experimental groups (P < 0.001). There was no significant difference in the fracture resistance between CR and BD groups (P = 0.998). GP and positive control groups were significantly lower resistance to fracture than the other groups (P < 0.001). CONCLUSIONS: Intraradicular reinforcement with BD + FP and CR + FP enhanced the fracture resistance of simulated immature teeth than the other experimental groups. CLINICAL RELEVANCE: Biodentine or composite resin combined with fiber post could be used to reinforce immature teeth with an apical Biodentine plug.


Asunto(s)
Compuestos de Calcio/química , Análisis del Estrés Dental , Ensayo de Materiales , Materiales de Obturación del Conducto Radicular/química , Silicatos/química , Fracturas de los Dientes/prevención & control , Resinas Compuestas/química , Gutapercha/química , Humanos , Técnicas In Vitro , Distribución Aleatoria , Factores de Tiempo
11.
Dent Mater ; 35(1): 185-193, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30509482

RESUMEN

OBJECTIVE: To evaluate the influence of titanium tetrafluoride (TiF4) incorporation on the physicochemical and antibacterial properties of Biodentine (BD; Septodont, Saint Maur des Faussés, France) as an intraorfice barrier material. METHODS: Three different proportions of TiF4 powder were used with BD; 1wt%, 2wt%, and 3wt%; respectively. BD without TiF4 addition was used as the control group. The setting time (ST) was determined using Gillmore needle apparatus. Diametral tensile strength (DTS) and fracture resistance were measured in a universal testing machine. Solubility was assessed using mass variation after 7days water storage. The hardness test was conducted using Vickers microhardness tester. The antibacterial activity was assessed using direct contact test against Enterococcus faecalis. Radiopacity was assessed and expressed in thickness of aluminum. Surface topography and elemental composition of modified BD were also assessed. The pH of soaking water was measured up to 168h. Data of tested properties were analyzed using one-way analysis of variance, the paired t-test, two-way repeated measures analysis of variance, and Tukey post hoc tests (P<0.05). RESULTS: BD-incorporating 2wt% TiF4 revealed the highest surface microhardness, DTS, and fracture resistance compared with the unmodified group (P<0.001). Higher concentrations of TiF4 (3wt%) compromised the solubility and prolonged the ST of BD (P<0.05). Bacterial growth of BD-incorporating TiF4 was significantly reduced when compared with the control group (P<0.05). The tested materials induced alkalization of the soaking water that decreased with time. SIGNIFICANCE: Biodentine-incorporating TiF4 (1wt% and 2wt%) is a promising intraorfice barrier material with enhanced physicochemical and antibacterial properties.


Asunto(s)
Antibacterianos , Fluoruros , Compuestos de Calcio , Ensayo de Materiales , Silicatos , Titanio
12.
Dent Mater J ; 38(2): 189-195, 2019 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-30381636

RESUMEN

This study evaluated the effect of titanium tetrafluoride (TiF4) solution on the bond strength of glass fiber post to resin cement. The specimens were divided into eight groups according to the method of surface treatment performed. Flexural properties and microtensile bond strength (µTBS) were determined. Data were analyzed using two-way ANOVA and Tukey's post hoc tests. The highest µTBS achieved with the TiF4 (4 wt/v%-4 min) group compared with the other groups (p<0.05). This finding could be attributed to the effectiveness of TiF4 (4 wt/v%-4 min) on removing the surface layer of the resin matrix of fiber posts that provides more uncovered surface areas of posts which improved the micromechanical retention of the resin cement. Surface treatments did not affect the flexural properties of fiber posts (p>0.05). Surface treatment of fiber post with TiF4 (4 wt/v%-4 min) solution exhibited higher bond strength to resin cement compared with other surface treatments.


Asunto(s)
Recubrimiento Dental Adhesivo , Técnica de Perno Muñón , Resinas Compuestas , Análisis del Estrés Dental , Fluoruros , Vidrio , Ensayo de Materiales , Cementos de Resina , Propiedades de Superficie , Titanio
13.
J Endod ; 44(11): 1725-1730, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30409450

RESUMEN

INTRODUCTION: The aim of this study was to evaluate and compare the resistance to cyclic fatigue of the new One Curve (OC) instrument in double (S-shaped) and single curvature canals compared with other nickel-titanium rotary instruments. METHODS: Size 25/.06 of OC, 2Shape (TS), Vortex Blue (VB), ProFile Vortex (PV), and RaCe (RC) instruments were tested inside artificial canals with a single curvature (60° curvature, 5 mm radius) and double curvature (coronal curve, 60° curvature, 5 mm radius; and apical curve, 70° curvature and 2 mm radius) while immersed in saline at 37°C ± 1°C. The number of cycles to failure (NCF) was calculated, and the fracture surface was examined by using a scanning electron microscope. The data of NCF and fragment length were analyzed by using one-way analysis of variance and Tukey post hoc tests. The t test was performed between the data of fragment length in different curvatures. The level of significance was set at P < .05. RESULTS: The VB instrument had a significantly higher NCF compared with the other instruments in double (S-shaped) and single curvature canals (P < .05). There was no significant difference between OC and TS in the NCF in single, apical, and coronal double curvature canals (P > .05). The lowest NCF values were recorded for RC instrument in all curvatures (P < .05). CONCLUSIONS: The fatigue resistance of VB was greater than that of other instruments. OC and TS instruments displayed superior cyclic fatigue resistance than PV and RC instruments.


Asunto(s)
Instrumentos Dentales , Diseño de Equipo , Falla de Equipo , Ensayo de Materiales , Movimiento (Física) , Níquel , Preparación del Conducto Radicular/instrumentación , Titanio , Calor
14.
Clin Oral Investig ; 22(3): 1433-1437, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29030714

RESUMEN

OBJECTIVE: The aims of this study were to assess and compare the resistance to cyclic fatigue of XP-endo Shaper (XPS; FKG Dentaire, La Chaux-de-Fonds, Switzerland) instruments with TRUShape (TRS; Dentsply Tulsa Dental Specialties, Tulsa, OK, USA), HyFlex CM (HCM; Coltene, Cuyahoga Falls, OH, USA), Vortex Blue (VB; Dentsply Tulsa Dental Specialties), and iRace (iR; FKG Dentaire) nickel-titanium rotary instruments at body temperature. MATERIALS AND METHODS: Size 30, 0.01 taper of XPS, size 30, 0.04 taper of HCM, VB, iR, and size 30, 0.06 taper of TRS instruments were immersed in saline at 37 ± 1 °C during cyclic fatigue testing. The instruments were tested with 60° angle of curvature and a 3-mm radius of curvature. The number of cycles to failure (NCF) was calculated and the length of the fractured segment was measured. Fractographic examination of the fractured surface was performed using a scanning electron microscope. The data were analyzed statistically using Kruskal-Wallis H test and Mann-Whitney U tests. Statistical significance was set at P < 0.05. RESULTS: XPS had a significantly greater NCF compared with the other instruments (P < 0.001). The topographic appearance of the fracture surfaces of tested instruments revealed ductile fracture of cyclic fatigue failure. CONCLUSION: XPS instruments exhibited greater cyclic fatigue resistance compared with the other tested instruments. CLINICAL RELEVANCE: XP-endo Shaper instruments could be used more safely in curved canals due to their higher fatigue resistance.


Asunto(s)
Instrumentos Dentales , Análisis de Falla de Equipo , Aleaciones Dentales/química , Diseño de Equipo , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Níquel/química , Estrés Mecánico , Propiedades de Superficie , Titanio/química
15.
Odontology ; 105(2): 178-183, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27206916

RESUMEN

The purpose of this study was to assess the efficacy of the XP-endo Finisher (FKG Dentaire SA, La Chaux-de-Fonds, Switzerland) file on debris and smear layer removal in curved root canals in comparison to different irrigation regimens. Seventy-five freshly extracted human mandibular molar teeth with mesial root curved more than 20° were used in this study. The mesial root canals were mechanically prepared using the BT-Race rotary system (FKG Dentaire) and divided into five groups (n = 15) according to the following irrigation techniques: positive control, non-agitated, File agitation, XP-endo Finisher, and EndoActivator (Dentsply Tulsa Dental Specialities, Tulsa, OK, USA). Root canals were split longitudinally and evaluated by scanning electron microscopy. Five-grade scoring system was used to assess the presence of debris and smear layer at the coronal, middle, and apical regions. The XP-endo Finisher and EndoActivator groups revealed significantly lower debris and smear layer scores than the other groups at the coronal, middle, and apical regions (P < 0.05). There was no significant difference between XP-endo Finisher and EndoActivator groups (P > 0.05). The apical region had higher debris and smear layer scores compared with the coronal regions in all groups (P < 0.05), except for the positive control group; there was no significant difference between the three regions of the root canal (P > 0.05). Irrigation of curved root canals using XP-endo Finisher and EndoActivator methods appears to be more effective on debris and smear layer removal than the other tested groups.


Asunto(s)
Instrumentos Dentales , Irrigantes del Conducto Radicular/química , Preparación del Conducto Radicular/instrumentación , Capa de Barro Dentinario , Cavidad Pulpar , Diseño de Equipo , Humanos , Técnicas In Vitro , Microscopía Electrónica de Rastreo , Diente Molar , Reproducibilidad de los Resultados , Irrigación Terapéutica
16.
Quintessence Int ; 48(1): 27-32, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-27669727

RESUMEN

OBJECTIVE: To evaluate and compare the volume of removed dentin, transportation, and centering ability of TRUShape (TRS; Dentsply Tulsa Dental Specialties) system with ProTaper Next (PTN; Dentsply Maillefer) by using micro-computed tomography (µCT). METHOD AND MATERIALS: Twenty extracted human mandibular first molars with two separate mesial canals with curvatures of 25 to 35 degrees were divided into two experimental groups (n = 20) according to the rotary nickel-titanium file system used in canal instrumentation as follows: group TRS and group PTN. Canals were scanned before and after instrumentation using µCT to evaluate root canal transportation, centering ratio, and volumetric changes. Data of canal transportation and centering ratio values were analyzed using independent t test. Volume changes data were statistically analyzed using Mann-Whitney test. Statistical significance level was set at P < .05. RESULTS: The PTN group had a significantly lower mean volume of removed dentin (2.09 ±â€¯0.41 mm3) than the TRS group (2.77 ±â€¯0.72 mm3) (P < .05). At the coronal level, there was no significant difference in canal transportation (P = .170) and centering ratio (P = .111) between TRS and PTN groups. However, at the apical and middle levels, the PTN group had a significantly lower mean transportation value and higher centering ratio than the TRS group (P < .05). CONCLUSION: Root canal preparation with the PTN system revealed better performance with fewer canal aberrations than the TRS system in curved root canals.


Asunto(s)
Instrumentos Dentales , Cavidad Pulpar/diagnóstico por imagen , Dentina/diagnóstico por imagen , Diente Molar/diagnóstico por imagen , Diente Molar/cirugía , Preparación del Conducto Radicular/instrumentación , Microtomografía por Rayos X/métodos , Aleaciones Dentales , Diseño de Equipo , Humanos , Técnicas In Vitro , Ensayo de Materiales , Níquel , Titanio
17.
Dent Mater ; 32(7): 908-14, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27087687

RESUMEN

OBJECTIVE: The aim of this study was to assess the mechanical properties of recently introduced zirconia reinforced lithium silicate glass-ceramic. METHODS: Two types of CAD/CAM glass-ceramics (Vita Suprinity (VS); zirconia reinforced lithium silicate and IPS e.max CAD (IC); lithium disilicate) were used. Fracture toughness, flexural strength, elastic modulus, hardness, brittleness index, and microstructures were evaluated. Data were analyzed using independent t tests. Weibull analysis of flexural strength data was also performed. RESULTS: VS had significantly higher fracture toughness (2.31±0.17MPam(0.5)), flexural strength (443.63±38.90MPa), elastic modulus (70.44±1.97GPa), and hardness (6.53±0.49GPa) than IC (P<0.001). On the other hand, VS glass-ceramic revealed significantly a higher brittleness index (2.84±0.26µm(-1/2)) (lower machinability) than IC glass-ceramic (P<0.05). VS demonstrated a homogeneous fine crystalline structure while, IC revealed a structure with needle-shaped fine-grained crystals embedded in a glassy matrix. The VS glass-ceramic revealed a lower probability of failure and a higher strength than IC glass-ceramic according to Weibull analysis. SIGNIFICANCE: The VS zirconia reinforced lithium silicate glass-ceramic revealed higher mechanical properties compared with IC lithium disilicate glass-ceramic.


Asunto(s)
Porcelana Dental , Litio , Circonio , Cerámica , Ensayo de Materiales , Silicatos , Propiedades de Superficie
18.
Indian J Dent Res ; 27(1): 37-41, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27054859

RESUMEN

CONTEXT: This study evaluated and compared the shaping ability of ProTaper Gold (PG) (PG; Dentsply, Tulsa Dental Specialties, Tulsa, OK, USA) system with ProTaper Universal (PU) (PU; Dentsply Maillefer, Ballaigues, Switzerland) using cone-beam computed tomography (CBCT) imaging. MATERIALS AND METHODS: Forty mesiobuccal canals of mandibular first molars with curvatures of 25-30° were divided into two experimental groups (n = 20) according to the rotary nickel-titanium (NiTi) file system used in canal instrumentation as follows: Group PG and group PU. Canals were scanned before and after instrumentation using CBCT scanner to evaluate root canal transportation and centering ratio at 3, 5, and 7 mm from the apex and volumetric changes. Data were statistically analyzed using independent t-tests and the significance level was set at P < 0.05. RESULTS: There was no significant difference between PG and PU systems in the mean volume of removed dentine, canal transportation, and centering ratio (P > 0.05). CONCLUSIONS: The PG and PU NiTi rotary systems showed similar root canal shaping abilities in the preparation of mesial canals of mandibular first molars.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Preparación del Conducto Radicular/instrumentación , Aleaciones Dentales , Instrumentos Dentales , Diseño de Equipo , Humanos , Níquel , Titanio
19.
Dent Traumatol ; 32(2): 116-20, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26381857

RESUMEN

BACKGROUND: The purpose of this study was to evaluate the long-term fracture resistance of simulated immature teeth filled with Biodentine (BD) and white mineral trioxide aggregate (WMTA) as pulp space barriers for regenerative endodontic procedures (REPs). MATERIALS AND METHODS: Sixty extracted human maxillary anterior teeth were divided into four groups of 15 teeth each. Positive control teeth received no treatment. The remaining teeth were prepared until a size 6 Peeso (1.7 mm) could be passed 1 mm beyond the apex. Then, an engineering twist drill of 3 mm diameter was used to extend the preparation of the canal 3 mm below CEJ. The root canals were irrigated and disinfected according to AAE considerations for REPs. The canals were filled with either BD or WMTA. The negative control canals were left unfilled. The coronal access cavities were restored with glass ionomer followed by composite resin. The teeth were placed in phosphate-buffered saline solution and stored for 12 months. Each specimen was then subjected to fracture testing using a universal testing machine. The peak load to fracture and the fracture resistance were recorded, and the data were analysed statistically. RESULTS: The positive control group had the highest fracture resistance and differed significantly (P < 0.05) from the other experimental groups. No significant difference was found between BD and WMTA (P > 0.05). CONCLUSIONS: Considering the risk of cervical root fracture for pulpless infected immature teeth treated with REPs, after 12 months, there was no difference between WMTA and BD regarding the resistance to root fracture.


Asunto(s)
Compuestos de Aluminio/química , Compuestos de Calcio/química , Óxidos/química , Materiales de Obturación del Conducto Radicular/química , Silicatos/química , Fracturas de los Dientes/prevención & control , Resinas Compuestas/química , Análisis del Estrés Dental , Combinación de Medicamentos , Cementos de Ionómero Vítreo/química , Humanos , Técnicas In Vitro , Distribución Aleatoria
20.
Odontology ; 104(1): 60-7, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25424595

RESUMEN

This study evaluated the effect of different surface treatments on the flexural properties and adhesion of glass fiber post to self-adhesive luting agent and radicular dentin. Seventy-five single-rooted human teeth were prepared to receive a glass fiber post (Reblida). The posts were divided into five groups according to the surface treatment: Gr C (control; no treatment), Gr S (silanization for 60 s), Gr AP (airborne-particle abrasion), Gr HF (etching with 9 % hydrofluoric acid for 1 min), and Gr M10 (etching with CH2Cl2 for 10 min). Dual-cure self-adhesive luting agent (Rely X Unicem) was applied to each group for testing the adhesion using micropush-out test. Failure types were examined with stereomicroscope and surface morphology of the posts was characterized using a scanning electron microscopy (SEM). Flexural properties of posts were assessed using a three-point bending test. Data were analyzed using ANOVA and Tukey's HSD test. Statistical significance was set at the 0.05 probability level. Groups treated with M10 showed significantly higher bond strength than those obtained with other surface treatments (P < 0.05). In general, improvements in bond strength (MPa) were found in the following order: M10 > C > S > AP > HF. Most failure modes were adhesive type of failures between dentin and luting agent (48.2%). SEM analysis revealed that the fiber post surfaces were modified after surface treatments. The surface treatments did not compromise the flexural properties of fiber posts. Application of M10 to the fiber post surfaces enhanced the adhesion to self-adhesive luting agent and radicular dentin.


Asunto(s)
Cementos Dentales/química , Dentina/química , Vidrio/química , Técnica de Perno Muñón , Cementos de Resina/química , Grabado Ácido Dental , Abrasión Dental por Aire , Análisis del Estrés Dental , Elasticidad , Humanos , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...